NYAD SERIES 100
MOISTURE ANALYZER
FlashPaper

Photo of Series 100FEATURES
  • Wide Dynamic Range: -100°C to +20°C Dew/Frostpoint
  • Selectable Units: °C, °F or PPM
  • Pressure (2000 psig) High Pressure (7000 psig)
  • Active Pressure Correction
  • Remote Sensor (to 1000 ft,)
  • Adjustable Alarm Contacts
  • Large 4 Digit LCD Display
  • Non-Volatile Data Memory
  • O.E.M Packaging
  • Gas or Liquid Samples
  • Analog Output (Voltage or Current)

 MOISTURE ANALYZER SYSTEMS WITH
STATE-OF-THE-ART FEATURES AND FLEXIBILITY

In any measurement, sensor capabilities determine the performance of the analyzer. For this reason, NYAD, INC. is proud to introduce the most advanced moisture monitoring system available.

The A.C.T. (Advanced Capacitive Transducer) moisture sensor uses state-of-the-art technology to produce a rugged, fast responding, trace moisture sensor that is also designed to lower your cost by permitting sensor replacement without having to discard old probe bodies.

The A.C.T. technology has a high specificity to moisture as well as dramatic improvements in its performance compared to older, competitive versions. The A.C.T. sensor is mounted on a probe containing digitizing electronics and calibration data in electronic memory – this means all moisture probes are completely interchangeable.

The Series 100 Analyzers features up to two software adjustable alarm set points, voltage or current analog output with adjustable zero and span, and user selectable dew point or concentration units.

The Series 100 Analyzers are available in several configurations to meet application requirements of explosion proof analyzers for natural gas to low cost monitors designed to meet the needs of O.E.M. compressed air suppliers.

Whichever system best meets your requirements, be assured that the “heart” will be the same: the unique NYAD Moisture Probe and the Series 100 Microprocessor Based Analyzer.


SPECIFICATIONS

Moisture Probe 
Type: NYAD A.C.T., Series 50 
Range: -100°C to +20°C Dew/Frostpoint
Accuracy: ±2°C NEMA-4: 9.5"W x 6.25"H x 3.5"D
Repeatability: ±0.5°C Portable: 8.5"W x 3"H x 9.25"D
Operating Temp: -130° to +70°C
Pressure Rating: 2000 psig.
High Pressure Rating: 7000 psig. Display: 4 Digit LCD, 0.5" High

Enclosures

Rack: 19"W x 5.25"H x 11.5"D
Panel: 10"W x 5.25"H x 11.5"D

Electronics

Alarm: SPDT, 1A @ 120 VAC
Output: 0 to 10 VDC, or 4-20mA
Power: 120 VAC 50/60 Hz., 1W Max

Nyad Logo

200 Mason Circle, Suite A, Concord, CA 94520
Ph: (925) 270-3971, Fax: (925) 270-3973

www.nyad.com